CM-CU385
Diesel generator set built around the Cummins NTA855-G4 engine, rated to ISO 8528-1.
- Standby rating
- 385 kVA
- Prime rating
- 350 kVA
- Engine platform
- NTA855-G4
- Frequency
- 50 Hz
Operating theatres, intensive care units, blood banks and imaging suites all need power that never blinks. Cunmi supplies silent and containerised sets qualified for hospital duty, including vaccine cold-chain packages specified to WHO PQS guidance.
A hospital standby system has to do more than start. It must transfer within the limits defined by IEC 60364-7-710 for medical locations, keep voltage deviation inside ±10 %, and stay quiet enough for a ward to sleep next to it.
We work with MEP consultants and biomedical engineers from the design stage, providing load calculations, single-line diagrams and acoustic reports for the tender package.

Each rating below is a published row from the brand model tables. Open Size range for the full span, or View for the engine and alternator details.
Diesel generator set built around the Cummins NTA855-G4 engine, rated to ISO 8528-1.
Diesel generator set built around the Perkins 1506A-E88TAG5 engine, rated to ISO 8528-1.
Diesel generator set built around the Baudouin 6M21G500/5 engine, rated to ISO 8528-1.
Automatic transfer switches designed for theatre and ICU circuits.
Super-silent canopies and resilient-mounted exhaust for ward-adjacent sites.
2 – 30 kVA packages for vaccine and blood-bank refrigeration, specified to WHO PQS guidance.
Factory test certificates, witness testing and O&M manuals supplied.
The same three stages run on every order, whatever the configuration: engineering before the quotation, a documented load test before packing, and support after the set is on site.

Load schedule, starting currents, ambient and altitude derating are worked through before a rating is proposed — the alternator is sized for the largest step, not the average.

Assembly, wiring and paint in one works, then a four-point load bank run at 25 / 50 / 75 / 100 % with the test sheet serial-numbered to the set.

Export packing, documentation and commissioning guidance, with spare-parts supply and remote diagnosis for the life of the installation.
The project behind the homepage card — what was asked, what we supplied and how it runs today.
The hospital's existing standby fleet was sized on paper figures. The facilities team wanted the replacement scheme proven against the building's actual demand before anyone signed the handover.
Three containerised sets carrying theatres and critical care, with the changeover sequence proven against the hospital's own load profile before handover — not against a lab figure.
The changeover has since been exercised on the real load, and the facilities team holds the test records for their accreditation file.

Technical articles and product updates relevant to this application.
Send us the load profile, site conditions and redundancy requirement. A Cunmi sales engineer will come back with a sized recommendation and budget quotation.
I'm ready to proceedSizing, paralleling, noise limits or grid codes — our application engineers answer specification questions before you commit to a configuration.
I have a questionConsumables, long-lead items and overhaul kits for the twenty most common platforms, held in regional hubs and quoted with honest lead times.
I have a service request