+86 151 5922 6809 cunmiwy@gmail.com Mon – Sat, 08:30 – 18:00 (GMT+8) Get a Quote
Containerized generator sets in containerized configuration

Containerized Generator Sets

Plug-and-play power in an ISO footprint

10 – 45 ft
Container footprints
Up to 4,125 kVA
Power range
IP54 (IP55 opt.)
Ingress protection
CSC
Container Safety Convention
Comparison Table

Technical parameters side by side

The table below compares the three enclosure types at equal electrical rating.

Technical ParameterOpen TypeSilent TypeContainerized
Typical power range10 – 4,125 kVA10 – 4,125 kVAUp to 4,125 kVA
EnclosureNone — open skidGalvanised acoustic canopy10 / 20 / 30 / 40 / 45 ft container
Ingress protectionIP21 (control panel IP54 optional)IP54IP54 (IP55 optional)
Ambient design temperature40 °C (50 °C optional)40 °C (50 °C optional)40 °C / 50 °C
Best suited toIndoor plant rooms, container frames, OEM integrationsHospitals, hotels, offices, telecom, residential standbyData centres, plants, offshore, rapid deployment projects
Factory testingLoad tested at 25 %, 50 %, 75 % and 100 % loadLoad tested at 25 %, 50 %, 75 % and 100 % loadLoad tested at 25 %, 50 %, 75 % and 100 % load
Why Containerized

Plug-and-play power in an ISO footprint

Because the package ships under a standard ISO envelope, freight, handling and site foundation costs drop sharply. Cunmi containers are available for both standby and parallel operation, with or without integrated switchgear.

Containerized — Ships like cargo, works like a plant
01

Ships like cargo, works like a plant

Because the package rides inside a standard ISO envelope, it moves by road, rail and sea at freight rates that bespoke enclosures never see — and arrives with the CSC plate already in place.

  • 20 ft / 40 ft ISO high-cube container, CSC plate certified
  • Internal day tank with bunded spill containment
  • Integrated exhaust silencer and horizontal air discharge
02

The plant room is built in

Walk-in layouts put the switchgear, lighting and ventilation behind a proper door instead of behind panels. Larger ratings add a separate control room, and synchronising panels make the container a building block for multi-set plants.

  • Separate control room with lighting, ventilation and fire detection
  • Optional LV/MV switchgear, synchronising panel and UPS circuit
  • Marine C5 grade protection with stainless-steel external panels
Containerized — The plant room is built in

A complete power plant, shipped in a standard envelope.

Project Cases

Delivered in containerized configuration

Reference deployments showing the rating, voltage and engine platform behind each configuration — the same build standard we apply to every order.

Containerized

Hospital power backup

3 × 1.6 MW · 400 V · 60 Hz

Baudouin 16M33G1650/6 + Leroy Somer LSA50.2 L8

Containerised standby for a healthcare facility where continuity is critical — low-noise, durable packaging that sits close to the buildings it protects.

Containerized

Data centre, mid-sized facility

4 × 1.6 MW · 400 V · 50 Hz

Mitsubishi S16R-PTA2-C + Leroy Somer LSA52.3 S6

Four containerised Mitsubishi sets carrying server rooms, network infrastructure and cooling with the redundancy a mid-sized facility requires.

Containerized

Data centre, large-scale campus

14 × 1.8 MW · 400 V · 50 Hz

Mitsubishi S16R2-PTAW + Leroy Somer LSA52.3 L9

A hyperscale deployment in a space-efficient containerised format, built for load sharing and phased expansion across the campus.

Containerized

Data centre, medium voltage

3 × 2 MW · 10 kV · 50 Hz

MTU 16V4000G63 + Marathon 1030FDH1250

A 10 kV containerised train feeding medium-voltage distribution directly, combining long service intervals with stable output for mission-critical load.

Planning a containerized project?

Tell us the load profile, voltage, frequency and site conditions. We will confirm the configuration, size the set and quote with the delivery lead time.

Other Configurations

If this one does not fit the site

Open Type

Rooms that already have their own acoustic treatment.

Silent Type

Sites with a noise limit and neighbours close by.

Which configuration suits your site?

Send us the site plan, noise limit and ambient conditions. We will recommend the enclosure type and confirm the acoustic performance.