Load Bank

Resistive and capacitive load banks for generator load testing — verifying output, voltage, frequency, cooling and protection systems before delivery.

Overview

Prove the performance, don't assume it

A generator set that has never run at full load has never been tested. Load banks apply a precise, controllable, repeatable electrical load so that the real performance of a generator — voltage regulation, frequency stability, temperature rise and fuel consumption — can be measured rather than assumed.

Cunmi supplies resistive and capacitive load banks for factory testing, site commissioning and periodic verification of standby plant, with particular focus on data centres and factories. Every load bank is available with automatic stepping, programmable load profiles and data logging for test reports.

load bank units
Product Types

Load bank product family

Product TypeCapacity Power Factor RangeTypical Application
ResistiveTo 1,000 kW per unitUnityCommissioning and periodic testing
CapacitiveConfigured per projectLeadingPower-factor and data-centre testing
Combined resistive / capacitiveConfigured per project0.8 lagging to unityFull load-bank commissioning
ContainerisedMulti-unit packagesUnityData centres, factories, rental fleets
Trailer-mountedTo 1,000 kWUnityMobile service and rental fleets
Specification

General technical specification

Exact ratings are configured per project. The table lists the standard parameter envelope of the Cunmi load bank range.

CapacityTo 1,000 kW per unit, paralleled for higher ratings
Voltage400 V – 11 kV, 50 Hz / 60 Hz
Load steps1 kW minimum resolution
ControlManual, automatic ramp, programmable profile
CoolingForced air, horizontal discharge
ProtectionOver-temperature, air-flow, phase imbalance
EnclosureIP23 indoor / IP54 containerised
InstrumentationPower analyser with harmonic measurement
Data loggingUSB, Ethernet, Modbus TCP
ComplianceIEC 60947, ISO 8528 verification
Applications

Where load banks are used

Factory acceptance testing

Verifies steady-state and transient performance of a generator set at rated load before it leaves the works.

Data-centre commissioning

Steps resistive and capacitive load through the commissioning sequence to prove cooling, protection and load acceptance.

Hospital emergency testing

Periodic full-load runs that keep standby plant verified between scheduled blackout tests.

Marine generator commissioning

Harbour and sea-trial loading for auxiliary and harbour generator sets.

UPS system verification

Capacitive steps validate leading power-factor capability without putting the real load at risk.

Rental fleet testing

Fast incoming and outgoing inspection of rental sets before every hire.

Gallery

Load bank in operation

Need a load bank for commissioning?

Tell us the generator rating, voltage and the tests you need to perform. We will specify the load bank capacity, step resolution and control interface.